<Description>
<DescriptionText><text>
</text></DescriptionText>
<DescriptionText><text>
Disables the checking of the sensors on the Table_Tilt_Cylinder.  The sensors
indicate cylinder extended and cylinder retracted.   When nts=1 then the
firmware
will not check the position of the cylinder after causing it to move.
</text></DescriptionText>
<DescriptionText><UnnumberedList>
<ListItem><Text>This parameter also works the same way for the Table_Stow_Cylinder.</Text></ListItem>
</UnnumberedList></DescriptionText>
<DescriptionText><text>
Disables the checking of the sensors on the Table_Stow_Cylinder.  The sensors
indicate cylinder extended and cylinder retracted.  When nts=1 then the firmware
will not check the position of the cylinder after causing it to move.
</text></DescriptionText>
<DescriptionText><UnnumberedList>
<ListItem><Text>nts=0 indicates sensor is installed</Text></ListItem>
<ListItem><Text>nts=1 indicates No sensor</Text></ListItem>
</UnnumberedList></DescriptionText>
</Description>
<Type>
integer
</Type>
<Default>
<UnnumberedList>
<li>0</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>0 to 1</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Notes>
<DescriptionText><text>
Table_Tilt_Cylinder tilts the table for load and unload.
</text></DescriptionText>
<DescriptionText><text>
Table_Stow_Cylinder together with Table_Tilt_Cylinder tilts the table to the
eject
position for feeding the plate into the conveyer.
</text></DescriptionText>
<DescriptionText><text>
If sensor disabled (nts=1), Firmware defaults to using time delay instead of
waiting for the cylinder extended (or retracted) sensor to become true.
</text></DescriptionText>
<DescriptionText><text>
timer: in milliseconds set by SET ALDLY TTILT. When the sensor is enabled a
timeout
error if generated is the cylinder extended (or retracted) sensor does not
become true
with in a certain time. The same value is used for timeout when sensor is
enabled.
</text></DescriptionText>
</Notes>
<Partition>
cal
</Partition>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../nvs/aldly_cal_ttilt.xml</LinkAddress><LinkTitle>NVS: aldly ttilt</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:35:40 2008 PST
</Updated>
<Links>
<Link><LinkAddress>http://techplanet.creo.com/output/computer_to_plate/platesetter_3244/nav/abbrev.htm</LinkAddress><LinkTitle>Other: Platesetter Acronyms and Definitions</LinkTitle></Link>
</Links>
</Parameter>